Field case: a 5 cm shadow cut a panel to 30% of its power
A real customer case. Why a small shadow next to an air conditioner crippled a flexible panel, why the 48 V battery stopped charging, and how we are fixing it.
Short answer: the panel was not faulty. Two things combined: a small moving shadow on a panel with no bypass diodes between its cells, and a string voltage too close to the battery voltage for the charge controller to work. The fix is a panel with more bypass diodes and a buck-boost controller. New samples are being tested now, and we will update this page with the results.
Customer details are withheld. The measurements are the customer’s own.
What the customer reported
A customer ordered two panel designs from us. One worked well. The other, they told us, was badly underperforming.
That panel was a custom design: 31 V at maximum power (Vmp), 39 V open-circuit (Voc), 3.3 A, with all cells in one series string and no bypass diodes between cell groups. Two panels were wired in series, about 62 V, to charge a battery with a full-charge voltage of 57.6 V through a 100 V MPPT controller.
What we found
Photos of the installation showed the panels mounted next to an air conditioning unit. Apart from around midday, part of the panel was in its shadow for most of the day.
The customer then measured the effect:
| Shadow on the panel | Output |
|---|---|
| None | 100% |
| About 5 cm (2 in) | About 30% |
| About 10 cm (4 in) | Under 10% |
Cause 1: one shaded cell limits the whole string
In a series string, every cell carries the same current. A shaded cell can’t pass the full current, so it holds back every other cell. Without bypass diodes, there is no path around it. That is why a shadow covering a few percent of the surface removed 70–90% of the power.
A shaded cell also turns the other cells’ energy into heat, which is how hot spots start.
Cause 2: the string voltage was too close to the battery voltage
A standard (buck) MPPT controller can only charge when the panel voltage is higher than the battery voltage, usually by a few volts to start.
- String Vmp: about 62 V at 25 °C
- Battery full-charge voltage: 57.6 V
That leaves about 4 V of margin on a cool, clear day. Panel voltage falls by roughly 0.3% for every °C the cells heat up, so on a hot roof the string can drop to around 56 V, below the battery. Add any shading and the controller simply stops charging.
Neither cause is a defect in the panel. But from the customer’s side it looked exactly like one.
The fix we proposed
- More bypass diodes. A new panel with eight bypass diodes, so a shadow only removes the shaded section instead of the whole panel.
- A higher panel voltage. About 56 V per panel.
- A buck-boost MPPT controller with a 150 V input limit. It charges whether the panel voltage is above or below the battery voltage, so a partly shaded panel keeps charging.
- Parallel wiring. Each panel works on its own, so shade on one doesn’t pull down the other, and the array stays far below the controller’s 150 V limit.
- Less shade, if possible. Moving the panel away from the air conditioner is the cheapest improvement of all.
Status: new samples are with the customer for testing. We will publish the measured results here.
What this means for your project
- Tell your supplier about anything that casts a shadow: air conditioners, vents, racks, antennas.
- Ask how many bypass diodes the panel has, and how it behaves in partial shade.
- Check the string’s Vmp against your battery’s full-charge voltage, at high temperature, not only at 25 °C.
- For 48 V batteries, consider a boost or buck-boost controller instead of forcing the panel voltage up. See solar charging for 36 V and 48 V batteries.
Send us your roof layout and battery voltage with your inquiry, and we’ll check both before quoting.